Oftalmol Zh.2010;1:91-94.

http://doi.org/10.31288/oftalmolzh201019194

NEW METHOD OF ACOUSTIC CONTROL IN CHOICE OF OPTIMAL PARAMETERS OF LASER TRANSSCLERAL CYCLOCOAGULATION IN PATIENTS WITH OPEN ANGLE PSEUDOEXFOLIATIVE GLAUCOMA

Klyuev G. O.

Odessa, Ukraine

There was developed the method of acoustic on-line monitoring of laser influence in performing transscleral cyclocoagulation and acoustic sensor for registering thermoelastic disturbances and effects ofpopcorn, which allowed to decrease the risk of complications, to increase safety of application of the method at the expense of directed management of the energy parameters of action. The autonomous acoustic sensor can be used in the clinical practice in set with any monofiber transscleral probes.

 

References

1.Клюев Г. О. Эффект «попкорна» при транссклеральной диодной лазерной циклокоагуляции // XI Съезд офтальмологов Украины, — Одесса, 2006. — Офталь-мол. журн. — 2006. — №3. — С. 78-81.

2.Клюев Г. О., Привалов А. П., Холин В. В. Контатктно-компрессионная   транссклеральная лазерная циклокоагуляция в лечении рефрактерных глауком // Фотобиология и фотомедицина. — 2007. — Т. 5. — №1,2. — С. 31-37.

3.Клюев Г. О. Эффективность модифицированной стандартной методики лазерной транссклеральной циклокоагуляции // Актуальні питання медичної науки та практики: Зб. Наук. праць — Вип. 69(2). — За¬поріжжя, 2006. — С. 56.

4.Пасечникова Н. В., Клюев Г. О., Привалов А. П. Изменение оптических свойств склеры и конъюнктивы при транссклеральной контактно-компрессионной передаче лазерного излучения // Офтальмол. Журн. — 2008-N. 3. — С. 83-87.

5.Echelman D. A., Stern R. A., Shields S. R., et al. Variability of contact transscleral neodymium: YAG cyclophotocoag¬ulation // Invest. Ophtahalmol. Visual Science. - 1995. -Vol. 36. - N. 2. - P. 497-502.

6.Grueb M., Rohrbach J. M., Bartz-Schmidt K. U., Schlote T. Transscleral diode laser cyclophotocoagulation as primary and secondary surgical treatment in primary open-angle and pseudoexfoliatve glaucoma // Graefe's Arch. Clin. Exp. Ophthalmol. - 2006. - V. 244. - N. 3. - P. 1293¬1299.

7.Hoerauf H., Mbller M., Hbttmann G., et al. Real-time imaging of transscleral diode laser cyclophotocoagulation by optical coherence tomography // Graefe's Arch Clin Exp Ophthalmol. - 2007. - V. 245. - N9. - P. - 385- 390.

8.Kramp K., Vick H. P., Guthoff R. Transscleral diode laser contact cyclophotocoagulation in the treatment of different glaucomas, also as primary surgery // Graefes. Arch. Clin. Exp. Ophthalmol. - . 2002. - Vol. 240. - N. 9. -P. 698-703.

9.Murphy C. C., Burnett C. M., Spry P. G. A two centre study of the dose-response relation for transscleral diode laser cyclophotocoagulation in refractory glaucoma // Br. J. Ophthalmol. - 2003. - Vol. 87. - N. 10. - P. 1252 - 1257.

10.Oberheide U., Bruder I., Welling H., Ertmer W. Lu-batschowski H. Optoacoustic imaging for optimization of laser cyclophotocoagulation //J. Biomed. Opt. - 2003. - V. 8. - N. 2. - P. 281-287.

11.Oberheide U., Lee C., Krebs R., et al. Therapy Monitoring of Laser Cyclophotocoagulation // Laser Physics. -2003. - Vol. 13. - No. 5. - P. 730- 734.

12.Preullner P.-R. Controlled cyclophotocoagulation // Der Ophtamologe. - 1998. - V. 95. - N. 9. - P. 645-650.

13.Preussner P.-R., Boss N., Fabbender K. et al. Real-time control for transscleral cyclophotocogulation // Graefe's Arch. Clin. Exp. Ophthalmol. - 1997. - Vol. 235. -N. 6. - P. 794-801.

14.Rebolleda G, Munoz F. J, Murube J. Audible pops during cyclodiode procedures //J. Glaucoma. -   1999. - Vol. 8. - N. 3. - P. 177-183.

15.Rosenow S., Stave J., Langnau E., et al. Cyclophotoco-agulation: experimental investigations of dosage problems // Graefe's Arch. Clin. Exp. Ophthalmol. -   1999. - V. 237. - N. 5. - P. 583-592.

16.Spencer A. F., Vernon S. A. «Cyclodiode»: results of a standard protocol // Br. J. Ophthalmol. - 1999. - Vol. 83. - P. 311-316.

17.Wahl J., Preussner P., Controlled Cyclophotocoagulation //Med. Laser Application. - 2002. - Vol. 17. - N. 4. - P. 341-346.