J.ophthalmol.(Ukraine).2012;5:51-56.

Full text Pdf 


http://doi.org/10.31288/oftalmolzh201255156

STRUCTURAL CHANGES OF THE VESSELS OF THE MEDULLAR RADIATION OF THE RETINA AND CHORIORETINAL COMPLEX IN THE RABBIT UNDER THE EFFECT OF HIGH FREQUENCY ELECTROWELDING OF THE BIOLOGICAL TISSUES IN MODELING INTRAOCULAR HEMORRHAGE

Pasechnikova N. V., Vit V .V., Naumenko V. A., Umanets N. N.

Odessa, Ukraine

It was established on the model of the intraocular hemorrhage in rabbits that the application of high frequency electrowelding of the biological tissues (modified generator EK-300M1) with parameters of the electric current: voltage— 18—20 W, strength —up to 0.1 A, exposition — 1—2 s, frequency — 66 kHz causes coagulation of the main vessels of the retina and obliteration of their lumen with phenomena of coagulation necrosis of the retina in the area under the effect; in this case its degree is significantly less than in diathermocoagulation with the parameters: voltage -10 W, frequency — 365 kHz, exposition — 1—2 s.

 

References

1.Rizzo S. Injection of intravitreal bevacizumab (Avastin) as a preoperative adjunct before vitrectomy surgery in the treatment of severe proliferative diabetic retinopathy (PDR) / Rizzo S., Genovesi-Ebert F, Di Bartolo E. [et al]. Graefes Arch. Clin. Exp. Ophthalmol. — 2008. — Vol. 246. — P. 837— 42.
Crossref

2.Moreira Junior C. Experimental studies with perfluoro-oc-tane for hemostasis during vitreoretinal surgery / Moreira Jbnior C., Uscocovich C., Moreira A. Retina. — 1997. — Vol. 17 (6). — P. 530— 4.
Crossref

3.Mathis A. Use of perfluorodecaline during vitrectomy for PDR / Mathis A., Pagot V., Idder A. [et al]. J. Fr. Ophthalmol. — 1993. — Vol.16. — № 11. — P. 584— 594.

4.Ho Sung Lee. Intraocular infusate with Hemocoagulase for the control of bleeding during vitreous surgery / Ho Sung Lee, Sang Ha Kim, In Taek Kim. Kor. J. Ophthal¬mol. — 1989. — Vol. 3. — P.6—10.
Crossref

5.Cheema R. A. Role of intravitreal bevacizumab (Avastin) injected at the end of diabetic vitrectomy in preventing postoperative recurrent vitreous hemorrhage / Cheema R., Mushtaq J., Al-Khars W. [et al]. Retina. — 2010. — Vol. 30. — P.1646 -50.
Crossref

6.Johnson M. Pars plana vitrectomy and direct diathermy for complications of multiple retinal angiomas / Johnson M., Flynn H., Gass J. Ophthalmic Surg. — 1992. — Vol.23. — P. 47— 50.

7.Патон Б. Е. Электрическая сварка мягких тканей в хирургии / Б. Е. Патон // Автоматическая сварка. — 2004. — № 9. — 0.7—11.

8.Пасечникова Н. В. Высокочастотная электросварка тканей заднего отдела глазного яблока (модифици-рованный генератор ЕК-300М1) с применением оригинального моно- и биполярного инструментария / Пасечникова Н. В., Уманец Н. Н., Артемов А. В. [и др.]. Офтальмол. Журн. — 2012. — № 2. — C.45- 49.
Crossref

9.Уманец Н. Н. Влияние высокочастотной элетросварки биологических тканей (модифицированный генератор ЭЕ-300М1) на длительность кровотечения из магистральных сосудов сетчатки при моделировании внутриглазного кровотечения у кроликов по сравнению с диатермокоагуляцией / Уманец Н. Н. Офтальм. Журн. — 2012. — № 4. — С.88-91.
Crossref