COMPARATIVE EVALUATION OF DIFFERENT METHODS OF THE CORNEAL CENTRAL THICKNESS MEASUREMENT

S. A. Rykov, Yu. N. Kondratenko, A. N. Novitsky, A. R. Kisil

Kiev, Ukraine

Measurement of the central corneal thickness is the essential component of the patient's examination in refractive surgery, surgery of cataract and glaucoma as well as making an adequate diagnosis and monitoring of glaucoma profile patients and patients with keratoconuses and keratectasies. The main problem of the existing measurement methods of the central corneal thickness is to determine the level of their reproduction and comparison of the data obtained. The paper presented the study of measurement reproduction and comparison of the pachymetry data of the most widely used instruments for CCT measuring (ultrasound pachymetry — based on ORA device, noncon¬tact keratotopography based on Orbscan II and noncontact endotelioscopy based on Topcon SP 3000).The above mentioned parameters are presented in total and at all measured ranges of the central corneal thickness at 20 um intervals. The study showed the greatest measurement reproduction in the contact ultrasound pachymetry. There was revealed the impossibility of direct interdevice comparison of the results of CCT measurements, therefore correction interdevice coefficients were proposed.

 

References

1.Алексеев В. Н., Литвин И. Б. Толщина роговицы как фактор риска развития первичной открытоугольной глаукомы // РМЖ Клиническая офтальмология. — 2009. — Т. 10, № 3. — С. 86- 88.

2.Катаргина Л. А., Киселева О. А., Арутюнян Л. Л. и со-авт. Значение центральной толщины роговицы в прогрессировании первичной открытоугольной глаукомы // Новости глаукомы. — 2010. — № 1. — C. 3-5.

3.Christensen A., NarvGez J., Zimmerman G. Comparison of central corneal thickness measurements by ultrasound pachymetry,   Konan  noncontact  optical pachymetry and Orbscan pachymetry // Cornea. — 2008. — Vol. 27, № 8. — P. 862- 865.
Crossref

4.Hashemi H., Roshani M., Mehravaran S. et al. Effect of corneal thickness on the agreement between ultrasound and Orbscan II pachymetry // J. Cataract Refract Surg. — 2007. — Vol. 33, № 10. — P. 1694- 1700.
Crossref

5.Lara F., Ferrfndez-SGnchez V., I^pez-Gil N. et al. Comparison of partial coherence interferometry and ultrasound for anterior segment biometry // J. Cataract Refract Surg. — 2009. — Vol. 35, № 2. — P. 324-329.
Crossref

6.Menassa N., Kaufmann C., Goggin M. et al. Comparison and reproducibility of corneal thickness and curvature readings obtained by the Galilei and the Orbscan II analysis systems // J. Cataract Refract Surg. — 2008. — Vol. 34, № 10. — P. 1742- 1747.
Crossref

7.Paul T., Lim M., Starr C. E. et al. Central corneal thickness measured by the Orbscan II system, contact ultrasound pachymetry and the Artemis 2 system // J. Cataract Refract Surg. — 2008. — Vol. 34, № 11. — P. 1906- 1912.
Crossref

8.Pillunat L. E., Kohlhaas M., Buhm A. G. et al. Effect of corneal thickness on applanation tonometry, pneumotonometry and tonopen measurements // Springer-Verlag Berlin Heidelberg. — 2006. — Vol. Glaucoma. — P. 65- 72.
Crossref

9.Touboul D., Roberts C., Kiirautret J. et al. Correlations between corneal hysteresis, intraocular preassure and corneal central pachymetry // J. Cataract Refract Surg. — 2008. — Vol. 34, № 4. — P. 616-622.
Crossref

10. U3akhan Ц. Ц., Ilzkan M., Kanpolat A. Corneal thickness measurements in normal and keratoconic eyes: Pentacam comprehensive eye scanner versus noncontact specular microscopy and ultrasound pachymetry // J. Cataract Refract Surg. — 2006. — Vol. 32, № 6. — P. 970-977.
Crossref