Contrast sensitivity in patients with pseudophakia after implantation of intraocular lenses of different models

D. G. Zhaboiedov

National medical university named after A. A. Bogomolets, Kiev (Ukraine)

Key words: cataract surgery, pseudophakia, visual functions, contrast sensitivity, estimation of indexes, mesopic and photopic conditions.

Investigation of the spatial contrast sensitivity (CS) after cataract surgery can more accurately assess the quality of the received vision functions. The purpose — to carry out a comparative analysis of CS in patients with implanted IOL of 5 different models.

Materials and methods. Studies were conducted in mesopic andphotopic conditions at low, medium and high spatial frequencies in different postoperative periods. Groups were formed according to the implanted IOL model — SA60AT, AOMI60, Tecnis ®, SN60WFand SL-907Centrix DZ.

Results and discussion. The study of CS values showed the advantage of IOL SL-907 Centrix DZ in all postoperative periods in mesopic (on average from 0.7 to 2.2 db (4.8-16.0 %)) and photopic (from 0.6 to 1.7 db (3,6-10,1 %), respectively) conditions (p < 0,05) at low and medium spatial frequencies. CS values in the high spatial frequencies were the same for all types of lenses. CS values were higher in the medium spatial frequencies compared to the low spatial frequencies average of 1.1 db (7.5 %) for all patients, but the highest degree was noted in the group with IOL SL-907 Centrix DZ — 1.2 db (7.4 %).

Conclusions. IOL SL-907 Centrix DZ has better CS indices compared to other models that allows to recommend it for wide application in cataract surgery for the purpose of better personalization in IOL model selecting for implantation.

References

1.Abbasova UA. Innovation in technology of phacoemulsi-fication (literature review). Oftalmologiya. 2010;4:81-6.

2.Isayev MA. Investigation of clinical and functional charac-teristics of the accommodative function of the eye in patients with monofocal IOLs of different designs: author's thesis for Candidate of Med. Science: 14.01.07. M.;2013. 24 p.

3.Kumalagov AKh, Voronin GV. Ergonomic ophthalmic research methods to assess the effectiveness of refractive surgery. Refraktsionnaia khirurgiia I oftalmologiia. 2005;5(3):30-1. Russian.

4.Malyugin BE, Tereshchenko AV, Belyi YuA et al. Com¬parative analysis of the clinical efficacy of implantation of spherical and aspherical IOL. Oftalmokhirurgiia. 2011;3:54-9. Russian.

5.Neroyev VV, Kogoleva LV, Katargina LA. Spatial contrast sensitivity in patients with retinopathy of prematurity. Ross. Oftalmol zhurn. 2013;4:34-7. Russian.

6.Filatov AV. Spatial contrast sensitivity with mono-and mul-tifocal pseudophakia in industrial workers. Kataraktalnaia I refraktsionnaia khirurgiia. 2011;3:32-5. Russian.

7.Shelepin YuE, Kolesnikova LN, Levkovich YuI. Illejie-nHH K). E. Визаконтрастометрия. Visual contrast measurement. Measurement of spatial transfer functions of the visual system. L.: Nauka; 1985. 85 p.

8.Franchini A. Comparative assessment of contrast with spherical and aspherical intraocular lenses. J Cataract Refract. Surg. 2006;32:1307-19.
Crossref

9.Montard R, Putz C, Creisson G et al. Aberrometry and contrast sensitivity after cataract surgery: aspherical IOL evaluation. J. Fr. Ophtalmol. 2008; 31(3):257- 62.
Crossref

10.Sandoval HP, FernGndez de Castro LE, Vroman DT et al. Comparison of Visual outcomes, photopic contrast sensitivity, wavefront analysis, and patient satisfaction following cataract extraction and IOL implantation: aspheric vs spherical acrylic lenses. Eye. 2008; 22(12):1469- 175. 11. Tzelikis PF, Akaishi L, Trindade FC et al. Spherical aberration and contrast sensitivity in eyes implanted with aspher-ic and spherical intraocular lenses: a comparative study. Am. J. Ophthalmol. 2008;145:827- 33.
Crossref