J.ophthalmol.(Ukraine).2016;3:15-18.

https://doi.org/10.31288/oftalmolzh201631518

Technological characteristics of cataract surgery in eyes with posterior chamber phakic intraocular lens implanted previously

D.O. Marshava1

Iu.M. Lazar, Cand. Of Sc. (Med.) 2

1Multiprofile clinics L/J

Kutaisi (Georgia)

2Fiatov Eye Diseases and Tissue Therapy Institute 

Odessa, Ukraine

E-mail: marshava-david@mail.ru 

Key words: cataract, phakic intraocular lens, bilensectomy

Introduction. Implantation of phakic intraocular lenses (PIOL) is used for the correction of high myopia. The problem of PIOL implantation is that cataract may develop in a long-term period after surgery due to the contact of constructive PIOL elements to anterior and posterior chamber tissues. So, the development of advanced surgical techniques enabling to perform bilensectomy as safely and quickly as possible is of a great importance.

The purpose of the present study was to improve the technique for cataract extraction in patients with posterior chamber PIOLs implanted previously.

Material and Methods. A total of 19 cases of cataract extraction in 11 patients with plus and minus models of posterior chamber PIOLs were studied. 12 of explanted PIOLs were made of collagen copolymer and 7 of them were of silicone.

Results. Endothelial cell loss (ECL) after bilensectomy averaged 9.1% in a study group. ECL increased after cataract phaco emulsification to 11% in 11 eyes at time point of 6 months after surgery and to 12.2% in 5 eyes with five-year follow-up.

There was noted a tendency of a more rapid visual function recovery (on the average, at Day 5 after surgery) and less endothelial cell loss when using the bilensectomy techniques improved. 

Conclusion. The improved bilensectomy technique enabled to perform effectively and safely the rehabilitation of patients with cataract with implanted PIOLs.

 

References

1.Agafonova VV. [Correction of ametropy via intraocular phakic lens] Thesis of Doctor of Science (Med). М.;2006:354. Russian. 

2.Dvali ML. [Intraocular correction of high myopia]. Vestn Oftalmol. 1986 Nov-Dec;102(6):29-31. Russian. 

3.Zuev V.K, [Modern aspects of surgical correction of high myopia]. Doctor of Medicine Thesis. Moscow, 1995. 40 p. Russian. 

4.Tumanyan ER. [Surgical correction of high degree myopia by minus IOL implantation]. Thesis for Dr. of Sc. (Med). M.; 1998. 353 p. Russian.  

5.Caramello G, Di Fortunato R. Three years experience of ICL implantation in high myopia. Congress of the ESCRS, 16th: Abstracts; Nice. 1998.

6.Maliugin BE, Uzunyan DG, Pokrovskiy DF. [Our experience of PIOL Staar for high myopia correction]. Modern Technologies of cataract and refractive surgery – 2008: Paper Collection. M.: 2006; 177-181. Russian.  

7.Sorokoletov G.V., Zuyev V.K., Tumanyan E.R., Veshchikova V.N. The first experience of posterior chamber phakic intraocular lens “pIOL-3” in high myopia. Oftalmokhirurgiia. 2013;4:25. Russian.  

8.Davidorf JM, Zaldivar R, Oscherow S. Posterior chamber phakic intraocular lens for hyperopia of +4 to +11 diopters. J. Refract. Surg. 1998;14(3):306-11.

9.Dejaco-Ruhswurm I, Scholz U, Pieh S et al. Long-term endothelial changes in phakic eyes with posterior chamber intraocular lenses. J. Cataract Refract. Surg. 2002;28(9):1589-93.
Crossref   Pubmed

10.Barinov EF, Agafonova VV. [Cause-and-effect approach to the study of complications after phakic intraocular ametropia correction]. Congress of ophthalmologists of Russia, the 8-th Conf.: Proceedings. M.; 2005. 243. Russian.

11.Cоolin J. Bilensectomy: the implication of removing phakic intraocular lenses at the time of cataract extraction. J. Cataract Refract. Surg. 2000; 26(1): 2-3.
Crossref   Pubmed