Офтальмол. журн. — 2022. — № 1. — С. 73-76.

УДК 617.7-007.681-089

http://doi.org/10.31288/oftalmolzh202217376


Trabeculoplasmy, a new surgical technique in the treatment of glaucoma: pilot report

Leopoldo Garduño Vieyra, Raúl Rúa Martínez, Verónica Muñoz Cornejo,  Héctor Bello López Portillo

Clínica Oftalmología Garduño; Irapuato, Guanajuato (México)

E-mail: ruamartinez@yahoo.es

ЯК ЦИТУВАТИ: VieyraLeopoldoGarduño. Trabeculoplasmynewsurgicaltechniqueinthetreatmentofglaucoma: pilotreport/ LeopoldoGarduñoVieyra, RaúlRúaMartínez, VerónicaMuñozCornejo, HéctorBelloLópezPortillo// Офтальмол. журн. — 2022. — № 1. — С. 73-76.   http://doi.org/10.31288/oftalmolzh202217376


The effectiveness of trabeculoplasmy in lowering intraocular pressure (IOP) in glaucoma patients was determined. A longitudinal study was carried out in 10 patients with open-angle glaucoma that underwent trabeculoplasmy. The postoperative results Of IOP, visual acuity (VA) and the occurrence of complications were evaluated at 24 hours, one week, 3, 6, 9 and 12 months. 10 surgeries were performed (10 eyes, 10 patients). Preoperative average IOP was 32.5mmHg and preoperative VA was 0.5. At one year the average IOP was 10.10 mmHg and the average VA was 0.7, both values were significant (p<0.001, p=0.019 respectively). Trabeculoplasmy may be effective technique in the treatment of glaucoma, providing a decrease and maintenance of IOP within normal limits after one year of follow-up.

Key words: glaucoma, intraocular pressure, surgery, trabeculoplasmy

 

References

1.Yee Melgar M. Terapias alternativas para el tratamiento del Glaucoma. Visión 2020 Latinoamérica Boletín Trimestral. 2013(26(3). Disponible en: https://vision2020la.wordpress.com/2013/03/26/terapias-alternativas-para...

2.Daljit S. Fugo Blade effective tool for multiple surgical applications.  Eurotimes 2008. Disponible en: http://www.escrs.org/Publications/Eurotimes/08June/FugoBladeeffective.pdf 

3.Fry Luther L.The Pros and Cons of the Fugo Plasma Blade. Cataract and Refractive Surgery Today. 2007. Disponible en: https://crstoday.com/articles/2007-oct/crst1007_19-php/ 

4.Dow CT, de Venecia G. Transciliary filtration with the Fugo plasma blade. Ann Ophthalmol (Skokie) 2008:40(1):8-14.

5.Susanna R Jr, Vessani RM. Staging glaucoma patients: why and how? Open Ophthalmol J 2009;3:59-64.

6.Singh D, Bundela RA, Agarwal A, Bist HK, Satsangi SK. Goniotomy ab interno “a glaucoma filtering surgery” using the Fugo Plasma Blade. Ann Ophthalmol (Skokie) 2006;38(3):213-7.

7.Jankowska-Szmul J, Dobrowolaki D, Wylegala E. CO2 laser-assisted sclerectomy surgery compared with trabeculectomy in primary open-angle glaucoma and exfoliative glaucoma. A 1-year follow-up. Acta Ophthalmol. 2018:96:e582-e591.

8.Roy H, Singh D, Fugo RJ. Ocular applications of the Fugo Blade. 1ra edición. Philadelphia: Lippin Cott Williams and Wilkins; 2011.

9.Lavia C, Dallorto L, Maule M, Ceccarelli M, Fea AM (2017) Minimally-invasive glaucoma surgeries (MIGS) for open angle glaucoma: A systematic review and meta-analysis. PLoS ONE12(8): e0183142. 

 

Authors do not have conflict of interest in this article.

Received 25.02.2021